INTRODUCTION OF THE SYSTEM Intended UseThe system is intended for use outside the body (in vitro diagnostic use). It should be used only for testing

Pagina 3

Your system includes: 1. A Meter 2. Owner’s manual 3. Sporty carrying case 4. Quick reference guide 5. Warranty Card PLEASE NOTECheck your system

Pagina 4 - TABLE OF CONTENTS

Located in front of the meter with “ ” on it, is used to turn on the meter, enter the memory mode and control steps of setting. m Appearance and Key F

Pagina 5

Meter Display SegmentsTEST STRIP SYM-BOLAppears when the meter is turned on.VOICE SYMBOLIndicates speaking function is on/o ff.BLOOD DRO P SYMBOLFla

Pagina 6 - IMPORTANT INFORMATION

Speaking FunctionWhen a talking symbol is on the meter, it means that the meter provides speaking function. It “speaks” step by step and leads you

Pagina 7

Appearance of the Test StripYour system measures the amount of sugar (glucose) in whole blood. Blood is applied to the absorbent hole of the test str

Pagina 8

PREPARATION BEFORE USE Battery Replacement Your meter comes with two 1.5V AAA size alkaline batteries. The meter will alert you when the power is get

Pagina 9

To replace the batteries, make sure that the meter is turned off.WARNINGAs with all small batteries, the batteries should be kept away from small chil

Pagina 10 - INTRODUCTION OF THE SYSTEM

Setting the Meter and Deleting the MemoryYour meter comes with the time, date, unit of measurement and unit of temperature preset. However if you rep

Pagina 11 - Contents of the System

STEP 2. Set the Month Press and release the button until the correct month appears. To move faster, hold the button down. With the correct month o

Pagina 12

Dear Advocate™ TD-4223 A/B System Owner:You have chosen one of the best blood glucose monitoring systems. This manual contains important information y

Pagina 13 - Meter Display Segments

STEP 5. Set the Minutes Press and release the button to advance one minute. To move faster, hold the button down. With the correct minute on the d

Pagina 14 - Speaking Function

STEP 8. Delete the MemoryWhen “dEL” and blinking “ ” symbol is displayed, if you do not want to delete memory, press the Set button again to skip th

Pagina 15 - Appearance of the Test Strip

STEP 9. Select Speaking Function The meter displays “VOL”, “ ” and flashing number. Press the button to select speaking volume from 0 to 7. Then p

Pagina 16 - PREPARATION BEFORE USE

BEFORE TESTING Checking the Display Each time you insert a test strip, the meter displays ”CH” and ” ”. This tells you that the system is performin

Pagina 17

Press the Code Button. With “Code” and “SEL” appear first, the flashing code number shows. Press the CODE button to advance one number until the corre

Pagina 18

TD-4223CODE63STEP 2. Match the Code NumberCompare the flashing number with the code number on the test strip vial. If two numbers match, press the b

Pagina 19

the meter and the test strips are working together as a system and that you are performing the test correctly. It is very important that you do this s

Pagina 20

Use only Advocate™ control solutions. Check the expiration date on the control solution vial. Do not use if expired. Control solution, meter, and te

Pagina 22

STEP 2. Press the buttonWhile the “ ” symbol appears on the display, press the button and then “CTL” will appear on the display. With the “CTL” s

Pagina 23 - BEFORE TESTING

IMPORTANT SAFETY INSTRUCTIONSREAD THIS BEFORE USINGThe following basic safety precautions should always be taken.1. Close supervision is necessary whe

Pagina 24

STEP 4. Apply Control SolutionMove your finger (with control solution on it) to meet the absorbent hole of the test strip and the drop will be automat

Pagina 25

TD-4223CODE TESTING YOUR BLOODBe sure to read this section and the test strip package insert found in the test strip box carefully before testing. Mak

Pagina 26

Testing ProcedureWash and dry your hands first before starting.STEP 1. Set the Lancing DeviceScrew off the cap of Lancing Device. Insert a lancet int

Pagina 27

The lancing device is now ready. Set aside for later use. Blood from sites other than the fingertipSlide the ejection/cocking control back until it cl

Pagina 29

FingertipHold the Lancing Device firmly against the side of your finger. Press the release button. You will hear a click, indicating that the punctur

Pagina 30 - Incorrect

When “ “ is flashing on the screen, apply your blood to the absorbent hole of the test strip until the confirmation window is fully covered with blo

Pagina 31 - TESTING YOUR BLOOD

STEP 6. Remove the Lancet Always use caution when removing the lancet.Take the lancet out carefully. Place the disk on a hard surface and push the exp

Pagina 32

Expected Test ResultsBlood glucose monitoring plays an important role in diabetes control. A long-term study showed that keeping blood glucose levels

Pagina 33

COMPARING METER AND LABORATORY RESULTSTest results from the meter and laboratory are both expressed in plasma-equivalent units. However, the result y

Pagina 34

TABLE OF CONTENTSIMPORTANT SAFETY INSTRUCTIONS 1IMPORTANT INFORMATION 4ABOUT ATERNATIVE SITE TESTING (AST) 6INTRODUCTION OF THE SYSTEM 8 Intend

Pagina 35

You may still have a variation from the result because blood glucose levels can change significantly over short periods, especially if you have recent

Pagina 36

With the meter turned off, press the button twice. The 7-day average will appear, indicating that you are in the memory mode. If you continue to pr

Pagina 37

It also indicates how many blood glucose tests have been performed within this period, e.g., 14 (14 tests in the last 7 days). The 14 day average is

Pagina 38

When reaching the last set of result, “End” and “ “ will be shown on LCD display, and the meter will be turned off automatically.STEP 3. Exit the Me

Pagina 39

PLEASE NOTE The control solution results are NOT stored in the memory (please also go to page 26 WARNING for information). The list of past result

Pagina 40 - Company ( 994), 959

Viewing Results on a Personal ComputerSTEP 1. Install SoftwareSTEP 2. Connect to Personal ComputerConnect the interface cable to a serial port of you

Pagina 41 - USING THE METER MEMORY

STEP 3. Transmit DataFollow the instructions provided in the software to transmit data. Results transmitted will include date and time. Remove the cab

Pagina 42

CARING FOR YOUR METER AND TEST STRIPSTo avoid the meter and test strips getting dirt, dust or other contaminants, please wash and dry your hands thor

Pagina 43

Avoid dropping and strong impact. Avoid direct sunlight and humidity. Store test strip packages in a cool and dry place. Keep away from direct sunli

Pagina 44

Use each test strip immediately after removing it from the vial. Write the discard date (the date opened plus 90 days) on the vial label when you fir

Pagina 45

COMPARING METER AND LABORATORY RESULTS 37USING THE METER MEMORY 39 Viewing Results on the Meter 39 Viewing Results on a Personal

Pagina 46 - STEP 3. Transmit Data

PROBLEM-SOLVING GUIDEFollowing is a summary of some display messages and symbols. These messages help to identify certain problems but do not appear

Pagina 47

Result IndicatorSpecial symbols and messages appear together with your test result.Message What it meansappears when your result is at reference rang

Pagina 48 - 2 Strip Storage

Error MessageMessage What it means Actio nAppear when the batteries can not pro-vide enough powerfor a test .Replace the batteries Immedi-atel y.Ap

Pagina 49 - 3. Control solution storage

Problem in Operation1. If the meter does not display a message after inserting a test strip: 2. If the test does not start after applying the sample

Pagina 50 - PROBLEM-SOLVING GUIDE

3. If the control solution test result is out of range:POSSIBLE CAUSE W HAT TO D OError in performing the test.Improper code number. Check if the co

Pagina 51 - Result Indicator

SPECIFICATIONSModel No.:TD-4223 A/BDimension&Weight: Power source: two 1.5V AAA alkaline batteries Battery life: Over 1,000 determinants Display:

Pagina 52 - Error Message

SYMBOL INFORMATIONSymbol ReferentDo not re-useIn vitro diagnostic medical deviceConsult operatinginstructionKeep away from sunlightKeep dryTemperatur

Pagina 53 - Problem in Operation

Advocate Warranty Registration InformationCustomer CareCall us with Questions or Comments about your Advocate Blood Glucose Monitor. We are here to he

Pagina 54 - POSSIBLE CAUSE W HAT TO D O

IMPORTANT INFORMATION Severe dehydration and excessive water loss may cause false low results. If you believe you are suffering from severe dehydrati

Pagina 55 - SPECIFICATIONS

The following WILL NOT affect results: Elevated blood triglyceride, reducing substances such as uric acid and ascorbic acid when occurring in expecte

Pagina 56 - SYMBOL INFORMATION

ABOUT ALTERNATIVE SITE TESTING (AST)Important: There are limitations for doing AST. Please consult your healthcare professional before you do AST.Wha

Pagina 57 - REF # 304

We strongly recommend you do AST ONLY in the fol -lowing intervals: In a pre-meal or fasting state (more than 2 hours since the last meal). Two hou